Products · 20–5000 VA

Products

Based on your enquiry, we manufacture the products you need to your specification.

Inside the transformer

The animated cutaway shows how a toroidal transformer is built: a toroidal core of transformer steel, copper windings, layers of insulation and the mounting kit.

Trafco transformer, boxes and mounting kit on a workbench
01 · up to 5000 VA

Autotransformers

An autotransformer, also known as a step-up or step-down transformer, has just one winding, tapped at the appropriate points. We build them up to 5000 VA.

The primary and secondary are not galvanically isolated, so the output carries the live phase and an autotransformer offers no protection. It most often supplies 110–120 V equipment, for example from the USA or Canada, that is designed for direct connection to the live phase without danger to the user.

Technical data

Power rating
up to 5000 VA
Winding
Single, tapped
Galvanic isolation
None
Typical use
110–120 V equipment on 230 V mains
Voltages
To customer specification
Warranty
24 months from the date of receipt

When the transformer must provide protection, choose an isolation transformer.

Technician winding a toroidal transformer in the Trafco workshop
02 · Galvanic isolation

Isolation transformers

An isolation transformer has separately wound primary and secondary windings, insulated from each other. It is also called a safety transformer: its secondary side has no galvanic connection to the primary mains phase, so it protects the user.

It is mandatory for medical equipment and for lighting in vehicle repair workshops and inspection pits.

An electrostatic screen can be wound between the primary and secondary, with one end connected to earth. It further reduces interference in audio equipment and gives extra protection against electric shock if the insulation between primary and secondary breaks down.

The Electrical Engineering Institute Nikola Tesla tested our 230/230 V, 500 VA toroidal isolation transformer with a thermal fuse to IEC 61558-1 and SRPS N.H8.010. Result: it complies with the regulations and is fit for purpose.

Technical data

Windings
Separate primary and secondary
Galvanic isolation
Yes
Electrostatic screen
Optional, connected to earth
Tested model
230/230 V, 500 VA, thermal fuse
Regulations
IEC 61558-1, SRPS N.H8.010
Applications
Medical equipment, workshop lighting
Soft Start printed circuit board with relay, resistors and fuse holder
Wiring diagram: Soft Start connected between the mains switch and the transformer
Soft Start circuit diagram
03 · 300–3000 VA

Soft Start

At switch-on, a toroidal transformer draws a large, brief inrush current while the core magnetises. As a result, fuses, and circuit breakers in particular, can trip even though the transformer is in perfect working order.

Soft Start limits the inrush current at the moment of connection to the mains. It is recommended for transformers rated 300–3000 VA with a 220 V primary. You can fit it in a suitable enclosure or directly inside the equipment.

How it works

Soft Start connects high-power resistors in series with the primary winding to limit the inrush current. After 0.5–1 s the relay contacts bypass the resistors, removing them from the circuit, and the transformer continues in normal operation. The process repeats automatically every time the power is switched off and on again.

The printed circuit board has a fuse holder for a fuse that protects the transformer against short circuit and overload. Choose the fuse rating for your transformer from the table in the installation instructions supplied with the unit. The fuse itself is not supplied.

Important: if the mains voltage is below 180 V, the Soft Start will burn out.

Technical data

Operating voltage
180–240 V
Maximum current
16 A
Transformer power rating
300–3000 VA
Transformer primary voltage
220 V
Resistor bypass
after 0.5–1 s
PCB version
75 × 55 × 25 mm, 0.06 kg
DIN version
55 × 75 × 110 mm, 0.175 kg
Fuse
Not supplied; choose it from the table in the instructions
Soft Start installation instructionsPDF · 696 KB
Made to order

Can’t see your voltage? We will wind it.

Send us the power rating, primary and secondary voltages and currents. We design the transformer for your equipment, from a single unit to a full series.